Ovay Reverse Osmosis Membrane Model Catalogue and Selection

The product line covers brackish water, ultra-low pressure, very low pressure, seawater and fouling resistant series. This library lists 42 elements, with models named in the OV/OP5/HC series.

42 elements · Source: manufacturer technical manuals, brochures and test data from official design software

Ovay is the RO membrane brand of Hunan Ovay Technology Co., Ltd., headquartered in Tianyuan District, Zhuzhou, Hunan Province. The company focuses on the development and manufacture of aromatic polyamide composite membranes, with products ranging from household membranes and industrial brackish water membranes to seawater desalination and fouling resistant membranes. It operates a complete process chain from membrane sheet casting to spiral-wound element assembly, which is the basis for its product line extending into both ultra-low pressure and fouling resistant directions.

According to public information, the company was founded in 2014 and is a national high-tech enterprise and a national-level specialised and sophisticated "little giant" enterprise. It is certified to ISO 9001, ISO 14001 and ISO 45001, and some membrane products hold US WQA, NSF/ANSI 58 and NSF/ANSI 61 certification. For potable-water and export projects these third-party certificates indicate batch consistency more clearly than a parameter table; public disclosures also state that the company's application for listing on the Beijing Stock Exchange has been accepted. Company information above is as published on the corporate website and in public disclosures.

The model system has two main lines: the OV series is organised by application (OV-U ultra-low pressure, OV-X very low pressure, OV-L low pressure, OV-FR fouling resistant, OV-SW seawater), while the OP5 series by rejection grade (OP5-10/OP5-20/OP5-30, where a higher number means higher rejection); HC/HP designates large-diameter and special-purpose models.

The number after OP5 is a common source of confusion in element selection: it denotes a performance grade rather than membrane area, and area is still read from the 400/440 in the model designation. Suffixes also carry meaning: -LE low energy, -HR high rejection, -MAX large-area version, -FR fouling resistant, -ECO economy version.

Coverage: 42 membrane elements for this brand, of which 32 are in 8040 format, 15 are seawater elements and 0 are NF membranes (large formats such as 16-inch included). Parameters are organised on a consistent basis, for comparison under identical conditions and for checking alternative models.

Series breakdown

SeriesPositioningRepresentative modelsTypical application
OV-UUltra-low pressureOV-U-8040-440, OV-U-8040-HR, OV-U-8040-ECOTap water and low-salinity groundwater, energy-sensitive projects
OV-XVery low pressureOV-X-8040 440, OV-X-8040Low-TDS feed, energy-reduction retrofit of existing systems
OV-LLow-pressure brackish waterOV-L-8040 440, OV-L-8040 400, OV-L-4040General industrial pure water, packaged systems
OV-FRFouling resistantOV-FR-8040 400, OV-FR-8040-LE, OV-FR-4040Surface water, municipal and industrial reuse water
OV-SWSeawater desalinationOV-SW-8040-HR400, OV-SW-8040-XHR 400, OV-SW-8040-LE440Single-pass seawater desalination, high-salinity wastewater
OP5Graded rejectionOP5-10, OP5-20, OP5-30, OP5-30MAXGrade chosen against the permeate TDS requirement; a higher number means higher rejection
HC/HP/RWLarge diameter and special purposeHC70, HC80, HP120, RW400Large systems, special separations (HC120/HC160 are low-rejection models)
Distribution of test pressure and stabilised salt rejection in the Ovay element library
Distribution of the 40 RO elements of this brand held in the library: test pressure 100~800 psi, stabilised salt rejection 99%~99.85%. Low-pressure brackish water elements are on the left, high-pressure seawater elements on the right, and rejection rises towards the top — when selecting, first locate the region that applies, then compare membrane area and pressure drop among models in that region.

Representative models and parameters

The table below lists representative models of this brand in 8040 format from the library (membrane area 365–510 ft² per element), sorted by area from largest to smallest; this format has 32 elements in total. The full model list can be filtered by brand in the design tool.

ModelMembrane area ft²Stabilised salt rejectionCategory
Source: manufacturer technical manuals, brochures and test data from official design software; standard test conditions are typically 2000 mg/L NaCl, 25℃ and 15% recovery, and actual performance must be calculated for the operating conditions.
HC8044099.4%Seawater desalination
OP5-20MAX44099.7%Brackish water RO
OP5-30MAX44099.6%Brackish water RO
OP5-30MAX-F44099.2%Brackish water RO
OV-L-8040 44044099.7%Brackish water RO
OV-SW-8040-HR 44044099.8%Seawater desalination
OV-SW-8040-LE44044099.7%Seawater desalination
OV-U-8040-44044099.6%Brackish water RO
OV-U-8040-440F44099.4%Brackish water RO
OV-X-8040 44044099.2%Brackish water RO
HC7040099.8%Seawater desalination
OP5-1040099.8%Brackish water RO
OP5-10LE40099.4%Brackish water RO
OP5-2040099.7%Brackish water RO
OP5-3040099.6%Brackish water RO
OV-FR-8040 40040099.8%Brackish water RO
OV-FR-8040-LE40099.6%Brackish water RO
OV-L-8040 40040099.7%Brackish water RO
Positioning of the Ovay OV and OP5 series by operating pressure and salt rejection
Ovay series positioning: the horizontal axis shows typical operating pressure bands, and the figures inside the coloured blocks on the vertical axis give the stabilised salt rejection range in this library. Very low pressure and ultra-low pressure suit low-salinity feed; the seawater series operates at the highest pressure.

How to select

Replacement and verification

The most common mistake in domestic substitution is treating a "corresponding model" as a direct equivalent. OV-U is positioned close to imported ultra-low pressure membranes, but membrane area (400/440), stabilised salt rejection and pressure-drop coefficients differ element by element. After replacement the software must re-solve the array and pressures, with particular attention to whether final-stage concentrate flow and per-element pressure drop exceed their limits.

At acceptance, batch sampling of actual permeate flow and rejection is advisable; large-area elements (440 ft²) are more sensitive to feed temperature and flux distribution, so sample data reflect consistency better than datasheet nominal values.

Official contact

OV Ovay
Emailovay@ovay.com.cn
Official websitewww.ovay.com.cn

Headquarters: Tianyuan District, Zhuzhou, Hunan Province. Contact details are as published on the company's official website.

FAQ

Is Ovay a domestic brand of RO membrane?

Yes. Ovay is the RO membrane brand of Hunan Ovay Technology Co., Ltd., headquartered in Tianyuan District, Zhuzhou, Hunan Province, with products covering brackish water, ultra-low pressure, seawater, fouling resistant and nanofiltration series.

When was Ovay founded?

Public information gives 2014 as the founding year; the company is a national high-tech enterprise and a national-level specialised and sophisticated "little giant" enterprise. For registration details, refer to the corporate website and public disclosures.

What is the difference between OP5-10 and OP5-30?

The number after OP5 denotes a performance grade: a higher number means higher rejection and usually higher operating pressure, not a larger membrane area. Select the grade against the permeate TDS requirement.

OV-U and OV-X are both ultra-low pressure: how do they differ?

OV-U is the ultra-low pressure main line, covering 400/440 ft² and including the HR high-rejection and ECO economy versions; OV-X is very low pressure, with lower operating pressure, suited to low-salinity feed and energy-reduction retrofits, and its rejection is slightly below that of OV-U-HR at the same area.

Can the OV-SW series be used on brackish water?

Technically it can operate, but seawater elements have different flux characteristics from brackish water elements; on low-salinity water they usually require higher pressure and are not economical, so select the series that matches the water type.

How can Ovay membrane parameters be verified?

This site lists 42 Ovay elements, with membrane area and stabilised salt rejection shown on this brand page; for formal design, use the manufacturer's latest datasheet and official software.

Note: this page is a technical compilation of public information and has no affiliation, agency or cooperation relationship with any membrane manufacturer; trademarks and model names mentioned belong to their respective owners. Parameters, series breakdown and software functions may change with manufacturer versions; for formal design, tendering and procurement, refer to the manufacturer's latest datasheet, official software and contractual terms. The content of this page does not constitute a selection commitment or quality guarantee.

Complete the design in your browser

Parameters for 733 membrane elements from 8 manufacturers, with same-condition comparison, project import and calculation report export (Excel/PDF/Word).

Log in to use See features